A microprocessor-controlled ventilator, designed by vets for vets.

S/N: V-22--1-02-449

- +
 

Flexible Finance
Options Available

On all orders over £500, call our sales team
to discuss 01622 834300

*Subject to status. Terms and conditions apply

SKU: VSL-MERLIN-cl

Graded Product

Grade 3 - Light scratching/marked or unessential accessory missing

*Image is a representation of product only and does not show actual condition of item

Graded Product

Grade 3 - Light scratching/marked or unessential accessory missing

*Image is a representation of product only and does not show actual condition of item

Details

One ventilator for all your small animal practice needs, from small rodents to large dogs.

 

No accessories included

The Vetronic Merlin veterinary ventilator has been designed with just that in mind. Using the latest technology, Merlin is able to precisely control ventilation parameters to ensure your patient is as safe as can be during mechanical ventilation. Merlin doesn’t require a compressed gas supply to operate, so is quiet and smooth. And, because Merlin is controlled by a state-of-the-art microcontroller, you can confidently set the independent ventilation parameters that you want, without compromise.

Merlin is a microprocessor-controlled ventilator, designed by vets for vets. We have done away with the conventional pressurised gas driving mechanism. This new ventilator uses a precisely-controlled piston that can accurately delivery volumes in the range 1ml to 800ml.

Merlin can be pressure cycled, volume cycled or time cycled and the inspiratory and expiratory times are fully and independently variable, without the need to re-adjust after changes in flow rates or volumes. A pressure control allows you to set the maximum allowable pressure during volume cycling, or the target pressure during pressure cycling.

A further added feature is the inspiratory assist control that will tune the ventilator to your patient during recovery and so assist weaning from the ventilator. On the front of the unit is a large, easily-readable display that shows all of your selected parameters. The parameters are continuously updated, reflecting every adjustment made.

In addition, we believe Merlin is truly innovative in being the first veterinary ventilator to calculate and display the compliance of the patient being ventilated.

 

Key features:

  • Precise, reliable control over all ventilation parameters
  • Fits into rebreathing and non-rebreathing circuits
  • Pressure cycled, time cycled or volume cycled IPPV
  • Patient disconnect and over-pressure alarms
  • 80-character screen and high-definition LEDs give full parameter information:
    • Tidal volume
    • Minute volume
    • Inspiratory and expiratory airway pressure
    • I:E ratio
    • Patient compliance
    • Respiratory rate
    • Inspiratory time
    • Expiratory time
    • Maximum allowed airway pressure
    • Assist effort
  • Purpose-designed stainless steel and silicon valves for precise flow control
  • Standard 22mm/15mm fittings
  • Suitable for anaesthesia or ICU
  • Mains powered with fail-safe operation
  • Assist mode

 

Mechanical

 

Electrical

 

General

 

S/N: V-22--1-02-449

More Information
More Information
Animal Small Animal
SKU VSL-MERLIN-cl
Aftercare

Protect your New Purchase
With A Care Plan From Burtons

Here for the life of your equipment, Burtons proudly offers a complete aftercare solution for much of our equipment range Including Maintenance plans, Waste gas monitoring, Equipment Repair and Calibration.

Why is an Equipment Care Plan
The Right Thing for your Vital Equipment?

Planned preventative maintenance is your best defence against sudden failure of vital, frequently used equipment. Much of the equipment we see in practice today has been recycled and is of an age where failure of components is highly likely unless routine maintenance is carried out.

By regularly having your equipment serviced you are extending the life of your equipment and ensuring it is working to its full ability
View all our aftercare options
Or call our team on 01622 834350 for more information
Reviews

Write Your Own Review

You're reviewing: Vetronic Merlin Small Animal Ventilator - Clearance


Good To Know...

At Burtons we know you have a choice to shop with us, that is why we always aim to delight our customers with a fast, easy, shopping experience. Making and sourcing only the best products we can find to fit your needs.

Price Matching: We regularly check all our prices against competitors so you don't have to. If you do find a like for like product cheaper we will aim to not just match it, but beat it!

Backorders: All back ordered items will be ordered and shipped as quickly as we can to you. Special order items may take up to 4 weeks. Once ordered a member of our team will be in contact to keep you informed of estimated delivery dates.

Returns Policy: You may return new, unworn or unused products within fourteen (14) days of delivery for a full refund of the cost of the goods, or an exchange if preferred. This is on top of your statutory rights.